Medrad Stellant Manual

broken image


Brings confidence and convenience to your international and diagnostic procedures.

Clear Direction. Ergonomics, Convenience, and Reliability. MEDRAD® Mark 7 Arterion has stylish ergonomics designed to increase mobility around a busy lab. Less time positioning and setting up the system means more time for the patient. The convenient front-load syringe design and MEDRAD® Twist & Go disposable syringe provide optimized pre- and post-procedure work flow.

Stellant service manual

Medrad Stellant Manual Pdf

MEDRAD® Mark 7 Arterion is a single-head injection system for X-ray angiography designed for high-end interventional radiology (IR) suites.

  1. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators.
  2. The MEDRAD ® Stellant FLEX offers continued focus on patient safety through its inventive design that aids in fluid visualisation; Syringe option to offer you the flexibility to optimise contrast media use, reduce the environmental impact, and cut the cost of unnecessary waste disposal, all of which can reduce operational costs.

Oct 04, 2017 MEDRAD STELLANT INJECTOR MANUAL. The primary subject for this pdf is generally covered about MEDRAD STELLANT INJECTOR MANUAL and finalized with all of the required and supporting information on.

Football manager 2006 patch 6.0.3 crack.

How does MEDRAD® Mark 7 Arterion work?

MEDRAD® Mark 7 Arterion allows the controlled delivery of radiopaque contrast media for interventional imaging purposes in interventional radiology, interventional cardiology and vascular surgery. The injector facilitates contrast delivery in fixed flow mode and variable flow with an optional software upgrading. It utilizes a dedicated 150 cc syringe (front load) and can deliver contrast media in phased mode.


What are MEDRAD® Mark 7 Arterion System Configurations and Main Components?

The MEDRAD® Mark 7 Arterion Injection System consists of three main components: Injector Head, Display Control Unit, and Power Supply. They are mounted with various options.

  • Pedestal Configuration
    The pedestal configuration combines all required injector components into an integrated, mobile unit
  • Table Mount Configuration
    This configuration option positions the injector head on the patient table, the DCU in the control room and the PS in the equipment (electronics) room
  • Overhead Counterpoise System Configuration
    The injector head can also be attached to an OCS system. Several versions accommodate most lab layouts
  • MEDRAD® Mark 7 Arterion Dual Display Option
    This option provides added flexibility allowing programming and control of the injector from two locations


How is MEDRAD® Mark 7 Arterion used?

The system is intuitively managed via the color touch screen DCU. All relevant information is displayed on the home screen where injection parameters can be programmed or changed. On the protocol screen up to 40 protocols can be stored, changed, deleted, or selected. A history tab allows to review the last 50 injections.

Standard:

IEC 60601-1

IEC 60601-1 (2nd and 3rd edition Amendment 1)

Medical electrical equipment, Part 1: General requirements for basic safety and essential performance

Standard:

IEC 60601-1-2

Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests

Size and

mobility

Footprint: 66.2 cm x 55.9 cm (26.1 in. x 22.0 in.)

Weight: 146 lbs. (66.22 kg)

Flow Rates

60 mL:

0.1-45.0 mL/s in 0.1 mL/s increments (single and phased)

0.1-59.9 mL/m in 0.1 mL/m increments (single mL/m)

150-200 mL:

1.0-10.0 mL/s in 0.1mL/s increments (variable)

Volume150 mL
Pressure Limits

60 mL:

100-1200 psi in 1 psi increments Moire remove gimp.

200 mL:

689-8273 kPa in 1 kPa increments

Rise Time0.0-9.9 seconds in 0.1s increments
Delay Time0.0-99.9 seconds in 0.1s increments
Fill Speed

Manual: 1-20 mL/s in 1 mL/s increments

Ablebits auto bcc keygen. Automatic: 1-10 mL/s in 1 mL/s increments

Syringe Size150 mL
Memory

Protocol: 39 Protocols (4 default, 35 storable)

Injection History: Approximately 50 injections

Flow Rate Accuracy

The Head shall inject fluid with a flow rate accuracy of ± (5% of programmed flow rate+0.25ml/s) in mL/s range as measured over 1 second, or 10mL, whichever is greater, while in fixed flow mode.

The Head shall inject fluid with a flow rate accuracy of ± (5% of programmed flow rate +0.25mL/m) in mL/m range as measured over 4 seconds or 1mL, whichever is greater.

The Head shall inject fluid with a flow rate accuracy of +/- (20% of the programmed flow rate +0.25mL/s) multiplied by the percentage commanded by the hand controller, while in variable flow mode.

Volume AccuracyThe Head shall deliver the programmed volume with an accuracy of ± (1.5% of programmed volume+2mL) in mL.

Standard:

IEC 60601-1

IEC 60601-1:2005+Amendment 1:2012*

Medical electrical equipment, Part 1: General requirements for basic safety and essential performance

Standard:

IEC 60601-1-2

IEC 60601-1-2:2014**

Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests

Medrad Stellant Manual Review

*Arterion has been designed and tested in accordance with the most recent medical equipment safety standard. This ensures Arterion is well suited for the current medical device environment.

**Arterion has been designed and tested in accordance with the most recent medical equipment electromagnetic compatibility standard. This ensures Arterion is well suited for the current medical device environment.

Bayer CT/CV injection systems are based on tried and tested technology with an excellent reliability track record.

An injector for X-ray angiography, engineered to meet the unique demands of your cardiac cath lab.

A CT injector system designed to minimize your injector touch time – so that you can spend more time focusing on your patients.

Ideal for your basic contrast injection needs, MEDRAD® Salient brings innovation and value to CT suites.

It is the injector of choice for advanced

Stellant Service Manual

CT applications such as cardiac and perfusion imaging.

Stellant Medrad Injector Manual

Ultravist® is an iodine-containing X-ray contrast agent, approved for all modern X-ray techniques water-soluble media.

I have a Medrad Stellant dual pistion injector, the contrast side is starting to stick and will not raise past a certain point when syringe is installed. However, the pistion can be raised up and down all day. I have cleaned down inside the well, wondering if there is a cleaner that will clean the piston and sleeve area or, does the unit have to be taken apart and cleaned or replaced. I do not have a service manual yet, gonna order that soon, guess I'll see if Medrad will throw me a bone. I really want to fix this problem myself, could use a little advice. I would imagine a good PM would fix this right up, however, the facility's contract with Medrad has expired and I have stepped up to the plate to take care of this unit.

Thanks Much,

Tim, Biomed.